Blumenthal EZ, Haddad A, Horani A, Anteby I.

Ophthalmology. 2004 Mar;111(3):435-9.
Comment in:
Ophthalmology. 2005 Jan;112(1):169; author reply 169-70.
Department of Ophthalmology, Hadassah University Hospital, PO Box 12000, Jerusalem 91120, Israel. eblumenthal@md.huji.ac.il

ABSTRACT:

OBJECTIVE: To evaluate whether healthy young children are able to perform automated static perimetry reliably using the frequency-doubling technology (FDT) perimeter. DESIGN: Prospective, observational case series.

PARTICIPANTS: Forty healthy children aged 4 to 14 years.

TESTING: Subjects underwent, in 1 randomly chosen eye, 2 consecutive visual field (VF) tests using the C-20 full-threshold program of the commercially available FDT.

MAIN OUTCOME MEASURES: Global measures included mean deviation (MD), pattern standard deviation (PSD), test duration and reliability indices, including fixation losses and false-positive and false-negative errors. Fixation losses are checked 6 times throughout the examination, rather than being continuously monitored. Two scoring systems, based on the total deviation probability plot, classified each VF as normal or abnormal. RESULTS: All subjects completed the VF test. The better of 2 examinations (as determined by the MD score) was used for analysis. The average test duration was 4.9+/-0.7 minutes for the entire group. The mean MD and PSD were -0.78+/-4.9 and 6.7+/-6.2, respectively. A clear correlation to age was found for MD, PSD, abnormality of the VF, and test duration (all P<0.05). Of all VFs, 32.5% were unreliable, such that at younger than 8 years of age, 42.9% of the VFs were unreliable, compared with 23.1% for those older than 8 years. Younger than 8 years of age, 78.6% of VFs were abnormal, whereas for ages 8 years and older, 26.9% of VFs were abnormal.

CONCLUSIONS: Frequency-doubling technology seems to be a clinically feasible VF method for evaluating young children older than approximately 8 years of age. The reliability indices, MD, test duration, and the reproducibility of the VF test were found to be highly correlated with age, in such a way that these parameters all improved with increasing age.

Article as Full-Text PDF

Glaucoma & Cataract:
www.glaucoma.org.il

Surgery

Diagnosis

This website was written by Prof. Eytan Blumenthal, to better understand glaucoma & cataract. This information should not replace medical consultation.

Related Posts

Risk Factors and Incidence of Ocular Hypertension After Penetrating Keratoplasty
Faik Oruc¸oglu, MD, Eytan Z. Blumenthal, MD, Joseph Frucht-Pery, MD, and Abraham Solomon, MD Journal of Glaucoma. 2013 Feb 19. Kudret Eye Hospital, Istanbul, Turkey Department of Ophthalmology, Hadassah-Hebrew...
List of Publications- by Prof. Eytan Blumenthal
ORIGINAL RESEARCH PAPERS Blumenthal EZ. Adjusting the slit-lamp oculars: An unnecessary burden or a must?  Survey of Ophthalmology 1995;40(3):225-228. Abstract Full-text (PDF) Blumenthal EZ, Serpetopoulos...
Adjusting The Slit-Lamp Oculars: An Unnecessary Burden Or A Must?
Blumenthal EZ. Surv Ophthalmol. 1995 Nov-Dec;40(3):225-8. Department of Opthalmology, Hadassah University Hospital, Jerusalem, Israel. ABSTRACT: Adjusting the slit-lamp eyepiece rings is perceived by some...
On Focusing The Slit-Lamp: Part I. An Inaccurate Ocular Setting--What Is There To Lose?
Blumenthal EZ, Serpetopoulos CN. Surv Ophthalmol. 1998 Jan-Feb;42(4):351-4. Department of Ophthalmology, Hadassah University Hospital, Jerusalem, Israel. ABSTRACT: Adjustments of the diopter rings on the...
Early Transient Visual Acuity Loss After Lasik Due To Steroid-Induced Elevation Of Intraocular Pressure
Frucht-Pery J, Landau D, Raiskup F, Orucov F, Strassman E, Blumenthal EZ, Solomon A. J Refract Surg. 2007 Mar;23(3):244-51. Department of Ophthalmology, Hadassah-Hebrew University Medical Center, Jerusalem,...